Categories
+ Cell engineering
+ Cell imaging
+ Cell isolation and culture
+ Cell metabolism
+ Cell movement
+ Cell signaling
+ Cell staining
+ Cell structure
+ Cell Transplantation
+ Cell viability
+ Cell-based analysis
+ Model organism culture
+ Organelle isolation
- Single cell analysis
Cell carrier
Cell counter
Flow cytometry
Laser capture microdissection
Mass cytometry
Microfluidics
+ Tissue analysis
Protocols in Past Issues

Determining Genome Size from Spores of Seedless Vascular Plants

LK Li-Yaung Kuo
YH Yao-Moan Huang
8875 Views
Jun 5, 2017
Seedless vascular plants, including ferns and lycophytes, produce spores to initiate the gametophyte stage and to complete sexual reproduction. Approximately 10% of them are apomictic through the production of genomic unreduced spores. Being able to measure the spore nuclear DNA content is therefore important to infer their reproduction mode. Here we present a protocol of spore flow cytometry that allows an efficient determination of the reproductive modes of seedless vascular plants.

Phenotyping of Live Human PBMC using CyTOFTM Mass Cytometry

ML Michael D. Leipold
Holden Maecker Holden Maecker
20337 Views
Jan 20, 2015
Single-cell analysis has become an method of importance in immunology. Fluorescence flow cytometry has been a major player. However, due to issues such as autofluorescence and emission spillover between different fluorophores, alternative techniques are being developed. In recent years, mass cytometry has emerged, wherein antibodies labeled with metal ions are detected by ICP-MS. In order for a cell to be seen, a metal in the mass window must be present; there is no analogous parameter to forward or side scatter. The current mass window selected is approximately AW 103-196, which includes the lanthanides used for most antibody labeling, as well as iridium and rhodium for DNA intercalators.

In this protocol, we use a cocktail of antibodies labeled with MAXPAR metal-chelating polymers to surface-stain live PBMC that have been previously cryopreserved. Many of these markers were taken from a standard fluorescence phenotyping panel (Maecker et al., 2012). No intracellular antibodies are used. We use a CyTOFTM (Cytometry by Time-Of-Flight) mass cytometer to acquire the ICP-MS data. Subsequent analysis of the dual count signal data using FlowJo software allows for cell types to be analyzed based on the dual count signal in each mass channel. The percentage of each cell type is determined and reported as a percent of the parent cell type.